Steakhouse chairs
The same hide, on four legs.
OpenWall runs, double-sided units and corner Ls, cut to the length on your drawing and knocked down so a 1,500 mm run clears a 900 mm door. Load goes down through the plinth, and the back is fixed to the frame rather than to a stud wall.








Back angle, seat depth and cushion. The back at 12 degrees from the wall keeps a guest upright over the plate, and most steakhouses settle between 15 and 18 once the average sitting passes 90 minutes.
Seat depth sits at 460 mm with a rolled front edge, and the roll is what stops the knee taking the whole lip. Cushion is 60 mm of 45 kg/m³ foam over an 18 mm plywood deck. Foam alone collapses where the same guest sits. The deck is what keeps a run level in year three.
One booth panel that ships whole does not go up a service stair and does not pass a 900 mm door without being cut on site, and a run cut on site ends up out of line at the corner.
Panels ship flat with a position letter on each, and the run bolts together in the order of the drawing. The mitre is cut from a template in the shop, never on the floor.
Hide on a booth takes more abuse than hide on a chair: it is leaned on, slid across and hit by the back of a belt. Channels stitched at 6 mm keep a knife nick inside one panel instead of letting it run the length of the back.
Cleaning is a cloth and a neutral cleaner. Conditioner every quarter keeps 1.4 mm hide from drying at the fold where the back meets the seat. That fold is the one place on a booth that cannot be patched invisibly.
Corners are where drawings and sites disagree most often. The mitre is cut from a template and the back panel returns 200 mm past the corner, so a guest turning into the seat does not meet an edge.
Curved runs are built on a bent plywood deck so the cover follows one radius. Stretching a flat cover around a curve costs less and shows within a year.
Per running meter of wall, at a stated depth and back height. Changes in depth or back height change the price per meter, so the drawing line matters more than the total length. Filler panels and end panels are quoted as separate lines.
Yes. Send the plinth height and the wall line. The toe kick is set 80 mm back from the seat edge as standard, and it can be cut to sit over a plinth instead of on the floor.
The same hide, on four legs.
OpenWhen a run has to move.
OpenGrades, cleaning, and re-covering.
OpenMeasured to the wall. The dining area is the sum of those runs.
OpenBooth runs are built level in the workshop, so any fall in the floor appears as a gap under one end of the plinth.
OpenSteakhouse aisle width runs 1,100 mm where a server passes a seated guest with a tray, and 900 mm where nobody passes.
OpenSeating for guests who find it hard to stand needs a seat 20 to 30 mm higher than standard, arms to push from, and a back that does not lean past 12 degrees.
OpenBooth runs fixed to the floor reduce the clear width of a dining area.
OpenSend the wall length, the seat count and the hide you have in mind. The answer comes back per line, with packing and a loading window.
Own workshop · EXW Foshan or DDP
Send the plan and the seat count. Answer inside two working days.
Chat on WhatsApp