Fourteen positions
Each one with the numbers that decide it.
OpenEvery booth run is bolted to the wall, so the floor in front of it is the only circulation the steakhouse will ever have. That distance is set at the drawing stage. Once the frames are bolted down, widening it means moving the run.
Fixed seating goes in first because it cannot be moved later. One run of 4.2 m takes seven seats at a 600 mm pitch. The same wall with loose tables takes five, and the two layouts are not interchangeable after the plinths are fixed.
Depth is the other half of it. Single booth depth at a wall is 600 mm, a double-sided island is 600 mm a side plus a shared back, and a bench with a loose chair on the aisle side is 600 mm of furniture plus 600 mm of pull-out. Those three numbers set how much floor is left before any table is placed.
Dining area width minus booth depth minus table depth minus chair pull-out leaves the aisle. On a 6.6 m dining area with booths both sides and a 900 mm table, that leaves 1,500 mm, which is a guest aisle with space to pass a tray in an emergency and not a service aisle every night.
Two numbers cover almost every dining area. At 900 mm two guests pass without turning sideways. At 1,200 mm a tray passes a seated guest, which is the line a steakhouse with table service has to hold on its main run. Mixing the two is how a dining area looks generous on the plan and feels tight at seven o'clock.
Clear wall at each run, measured without skirting. Door swing, because 900 mm behind a door cannot hold a seat. Column projections, which eat a seat each. The service route from the pass to the furthest table.
The 1,500 mm turning circle for accessible seating. And the egress width the local code asks for, which is a number to confirm rather than assume.
Run those six and the plan either holds or shows exactly which wall has to give. Running them after the furniture is quoted is how a dining area ends up with a booth that has to be shortened on site.
By one seat, at the factory, before it ships. On site it means cutting a welded frame and re-covering the end, which costs more than measuring the wall twice.
For a guest aisle between two rows, yes. For the main run that staff carry plates along, 1,200 mm is the number, and it is the one that gets cut first when a dining area is over-seated.
Each one with the numbers that decide it.
OpenTwo-top pitch, measured.
OpenThe nine numbers these rules rest on.
OpenSix checks run on your drawing.
OpenArm height at 200 to 220 mm above the seat lets a guest sit back without lifting the shoulder.
OpenSwivel counter stools let a guest get off without pushing the stool back.
OpenSteakhouse aisle width runs 1,100 mm where a server passes a seated guest with a tray, and 900 mm where nobody passes.
OpenDining table height at 750 mm matches a 460 mm seat with 280 to 290 mm between the top and the seat.
OpenDimensions, seat count and the finish you have in mind are enough to start. What comes back is a quantity per line, a leather card, a sample date and a loading window. All of it fits on one page.
Own workshop · EXW Foshan or DDP
Send the plan and the seat count. Answer inside two working days.
Chat on WhatsApp