Pitch
Seat pitch is the distance between the centre lines of adjacent covers.
Open4 August 2026
Covers per square metre is a subtraction before it is a division.
Take the aisles, the route to the door, the route to the toilets, the space in front of the counter and the egress width, then divide what is left by the pitch area. The dining area of 120 square metres does not hold 80 covers at 1.5 square metres each unless the service routes come out of somewhere else. Usable area typically comes out at 60 to 70 percent of the floor area in a full-service dining area, which is where the count differs from a naïve calculation.
Fixed seating changes the ratio, because a banquette gives more covers per square metre than loose chairs at the same pitch.
Pitch per cover is 600 mm for a loose chair and 1,100 to 1,200 mm for two on a banquette. Those are different numbers for the same person because the arm and shoulder clearance differs. Aisle width for service is 1,100 mm where a tray passes a seated guest, and 900 mm where nobody passes. Dining areas designed at 900 mm everywhere lose covers to the first busy night.
What a factory needs is a plan with dimensions, a section through the wall and the table heights. Everything else is inference, and inference is where the covers get lost. Standing space at the counter is 600 mm of width per person and 300 mm of overhang. Below either number the counter stops being usable at a busy service.
Accessible seating needs a 1,500 mm turning circle and a route of 900 mm. Those numbers come out of the cover count. The cover count is set first and the furniture follows. Chair pull out space is 300 mm behind the seat before the chair can be left without hitting the next one. That number, multiplied by the covers, is what an aisle actually costs.
Cover count is floor area divided by the space each cover needs, and that space is 1.1 to 1.4 square metres in a full service steakhouse. The dining area planned at 0.9 square metres per cover looks generous on a plan and unworkable on a Friday. Four tops need 2,000 by 1,700 mm for the same reason. Four covers at a 900 mm square table take 900 mm of table and 1,100 mm of circulation, and the diagonal is where the server walks. Our steakhouse furniture covers every model, size and finish.
Standing tables at 1,050 mm suit a dining area where guests arrive before the table is ready. The same height in a dining room reads as a mistake, because everyone eating at it is on a stool. Service routes should not cross guest routes. The path from the pass to the far corner that runs through the entry puts a server and an arriving party in the same square metre every service.
The pass to the furthest cover should be under 20 metres. The dining area where it is 30 metres runs on two extra staff and the food arrives colder at the same tables every night. Turn time and cover spacing are the same calculation seen from two sides. The space at 1,100 mm between tables turns twice. The same space at 1,300 mm turns 1.6 times and every guest stays longer. Thickness and base spread sit under grill room tables.
Measure the widest continuous aisle and multiply by the number of rows. If the answer is below 1,000 mm, the cover count is optimistic.
Seat pitch is the distance between the centre lines of adjacent covers.
OpenSteakhouse aisle width runs 1,100 mm where a server passes a seated guest with a tray, and 900 mm where nobody passes.
OpenSteakhouse two tops at 700 mm square give each guest 350 mm of edge and space for two plates and a bread plate.
OpenSeat height, pitch, clearance and the subtraction that gives a real cover count.
OpenDimensions, seat count and the finish you have in mind are enough to start. What comes back is a quantity per line, a leather card, a sample date and a loading window. All of it fits on one page.
Own workshop · EXW Foshan or DDP
Send the plan and the seat count. Answer inside two working days.
Chat on WhatsApp